Constantly strive for self-improvement,Carries goods with great virtue.
自强不息天行健,厚德载物人为本
标签模块
Performance Testing
Environmental test
Space target discovery and tracking
Remote sensing camera calibration in orbit
ABUIABACGAAg2o6E7wUomK6mpAQwvQI41gE

Stargazing test

Test star tracker static, dynamic attitudeefficiency, static accuracy, dynamic performance, polarity, and capture time inall-sky zone. The device is fixedly connected to the turntable, differentangular speeds of the rotation can be set to realize the measurement ofdifferent sky areas.



ABUIABACGAAg3YLf7gUoyLmP_QUwxAU4-wM

Dynamicaccuracy test

Thedynamic accuracy test is to verify the dynamic performance of the device bytesting the dynamic accuracy of the device under different angular velocitieson a high-precision turntable. The measurement of dynamic accuracy is thedifference between the actual rotation angle of the turntable and the rotationangle of the equipment. A parallel light pipe is used to simulate a single starpoint, and the turntable is used for external synchronous transmission. Thefalling edge of the FEN signal of the device triggers the turntable. Theturntable outputs real-time position through RS422. The device image is savedin real-time by the image transmission software and the angle value iscalculated. Internal exposure and line input compensation can verify thedynamic accuracy of the device.


ABUIABACGAAg-43f7gUo4Imhlgcw4BI4wAw

Installation matrix measurement

Measure the transformation matrix betweenthe device sensor coordinate system and the satellite coordinate system, (theprism can be the reference prism that comes with the device sensor or thereference prism for the entire satellite). Utilizing the self-collimationfunction of the theodolite, the system alignment measurement is performed tocalibrate the device sensor prism coordinate system and the satellitecoordinate system. It is used to measure the installation matrix betweenprisms, and equipment.


ABUIABACGAAg8Y3f7gUoyLrS4wcw7AQ4qQM

Stray light test

Test equipment stray light exclusion angle.Fix the device on the turntable, set different light intensity of the solarsimulator according to the test requirements, adjust the angle of the deviceand the solar simulator, make the optical axis direction of the device lenscoincides with the light path direction, record it as the zero degree position,adjust the rotation Record the working status of the equipment at differentangles to verify the stray light suppression performance.



ABUIABACGAAgj5Ty7gUoqKi3tgEwoAs4wAc

Vibration test

The frequency range of the electrical ShakerTables is 5-3500Hz, the maximum no-load acceleration is 1000m / s2, and themaximum speed is 1.8m / s, the maximum displacement is 51mm, the maximum loadis 300kg, and the effective weight of the moving table is 6kg. Its workingprinciple is the same as that of the loudspeaker, which is the current-carryingconductor is moved by the electromagnetic force in the magnetic field. When thecurrent passing through the moving coil of the vibration table generates anexciting force with an alternating signal, a vibration movement occurs. Theshaking table simulates the product vibration environment and is suitable forproducts working in a vibration environment such as national defense, aviation,and electronics. The tests include frequency sweep, sinusoidal vibration,random vibration, noise, and shock.



ABUIABACGAAghY-f7gUoyvew3QIwjwQ4igM

Thermal cycling

Programmable constant temperature andhumidity test chamber temperature range is -60 ~ + 150 , the volumeis 1000L. Constant temperature and humidity control system, PID control SSR, sothat the heating and humidification of the system equals the amount of heat andhumidity loss. The dry-wet bulb temperature measurement signal is compared withthe A / D conversion input controller CPU and RAN and output to the I / Oboard. The I / O board sends instructions to make the air supply system andrefrigeration system work and at the same time PID control SSR or heating SSR,or humidify SSR so that the amount of heat and humidity through the air supplysystem uniform test box to achieve a constant temperature and humidity.Applicable to the related industries such as optoelectronics, semiconductorindustry, auto parts, household appliances, various electronic components andso on.



ABUIABACGAAgsY7f7gUo882w-wEw4wk4qgc

Thermal vacuum

Vacuum degree can reach 5x10-5Pa,temperature range is -60 ~ + 120 . During the simulation test, the test piece is in a working state,placed in the vacuum tank, and the gas in the container is extracted to therequired value. The working parameters and environmental parameters of the testpiece verify the adaptability of the test piece in a vacuum environment. Thetest is mostly used to inspect the manufacturing process of spacecraft equipmentand find that the spacecraft equipment fails early.



ABUIABAEGAAg2JqV7gUoiIqmhQYwtwc4uwY

On February 19, 2019, the PST3 str tracker photographed on the ground and identified the photoelectric Morse code sent by the piaochong-1 satellite. The video shows that the star tracker attitude calculation can still work normally when the moon enters the field of view

In addition to the function of the conventional star tracker, our star tracker also has a spatial orientation measurement function. The star tracker can calculate the relative orientation between the target satellites by identifying the target optical satellite or other target optical signals and then calculate the spatial distribution of the target formation. This project has made its first flight on Longjiang-1. In order to further mature this technical solution, the company conducted a large number of outdoor tests and satellite-ground tests to verify the relative bearing measurement function.

ABUIABAEGAAg2JqV7gUoiIqmhQYwtwc4uwY

TY-space star tracker successfully identified Hefeng-1 satellite debris in stargazing test

PRESS
HOME
ADD: F3, 2# Building, 27# Longgang Road, Haidian District, Beijing, 100192  P.R.China
SERVICE
NEO
CONTACT
PRODUCTS
PUBLICATIONS